BIFMA HCF8.2 Draft Association Ballot Review
BIFMA recently closed its Association Ballot for BIFMA HCF8.2 – Health Care Seating – Tests. The comments will be reviewed and addressed by the committee on September 23rd. Based on our own review, we do not expect many negative comments and we expect BIFMA to proceed to the ANSI canvass before Christmas which means the ANSI approved standard version should be available in early spring 2016. This standard follows BIFMA HCF8.1 – Health Care Furniture Design – Guidelines for Cleanability – which was published October 2014. Contrary to BIFMA HCF 8.1 who deals with exposed surface’s chemical and UV resistance, BIFMA HCF8.2 is a mechanical and safety standard similar to BIFMA X5.1 , BIFMA X5.11 and very close to BIFMA X5.4. One could easily decide to test its product to BIFMA X 5.4 and HCF 8.2, size C all at once. You test once and comply to both standards. Micom voted affirmatively to this Association Draft Ballot Standard with only a few editorial comments.
BIFMA HCF8.2 is similar to BIFMA X5.4. However, whereas BIFMA X 5.4 is based only on a 253 lbs individual, BIFMA HCF8.2 offers tree user weight categories: ≤253 lbs, 254-400 lbs, 401-600 lbs. Other than the weight categories, there are only two new tests: #25 –Cycle Test for Recliners and #26 Legrest Strength Test. Not all chair variations will be required to be tested to establish your product line compliance to this new standard; a worst case scenario analysis to assess what needs to effectively be tested will have to be done on your product line.
This standard follows the release of BIFMA X5.11 “- General Purpose Large Occupant Office Chairs Tests” in 2015. This standard is meant for individuals having a corporal weight up to 400 lbs.
For more information about this test or other services we offer, please contact us.
Furthermore, please find in the table below a test-by-test comparison between BIFMA HCF8.2 and the other BIFMA Chair standards. We trust this will give you a good appreciation of how HCF8.2 relates to the other BIFMA standards.
NEW BIFMA STANDARD FOR HEALTH CARE SEATING |
|||||
Comparison between BIFMA HCF 8.2 (Pre-Association Ballot Draft) ANSI/BIFMA X5.1-2011, ANSI/BIFMA X5.11-2015 & ANSI/BIFMA X5.4-2012 |
|||||
Section # in HCF 8.2 |
BIFMA HCF 8.2 |
ANSI/BIFMA X5.1-2011 |
ANSI/BIFMA X5.11-2015 |
ANSI/BIFMA X5.4-2012 |
Comments |
Title |
Healthcare Patient Seating – Tests |
General Purpose Office |
General Purpose Large |
Lounge and Public Seating |
|
Scope |
Standard splitted in Size C: Individual ≤ 253 lb Size D: 253 < Individual ≤ 400 lb Size E: 400 < Individual ≤ 600 lb |
Standard based on a 253 |
Standard based on a 400 |
Standard based on a 253 |
|
Scope |
Tests developed expecting |
Tests developed expecting |
Tests developed expecting |
Tests developed expecting |
|
4. Classification |
Seating types are defined |
Chairs are defined as |
Chairs are defined as |
Seatings are defined as |
|
4. Minimum Seat Width |
Size C: > Size D: > 22″ Size E: > 26″ Measurement refers to BIFMA X5.11-section #5 |
No such requirement |
Chair width must be > 22″ |
No such requirement |
|
5. Backrest strength test |
150 / 250 lbf. per Initial pulling angle is 70° |
Test #5 & #6: 150 / 250 lbf. Initial pulling angle is 90° |
Test #6 & #7 150 / 250 lbf. Initial pulling angle is 90° |
Test #5: 150 / 250 lbf. Initial pulling angle is 90° |
BIFMA X5.4: same test as BIFMA X5.1 & X5.11 have specific test for Tilting and non-Tilting |
6. Backrest strength test |
200 / 300 lbf per seating |
No such requirement |
No such requirement |
200 / 300 lbf per seating |
BIFMA X5.4: same |
7. Backrest durability Test – Horizontal |
225 lb on each seat, 75 |
Test #15 & #16: 225 lb on seat, 120 000 cycles Type I: 100 lbf pull on backrest Type II & III: 75 lbf pull on backrest |
Test #15 & #16: 350 lb on seat, 75 lbf pull on backrest, 120 000 cycles |
225 lb on each seat, 75 |
BIFMA X5.4: same test as BIFMA X5.1 & X5.11 have specific test for Tilting and non-Tilting |
8. Backrest durability Test – Vertical |
200 lbf, all seating |
No such requirement |
No such requirement |
200 lbf, all seating |
BIFMA X5.4: same test as |
9. Arm strength Test – |
Distance between arms 100 lbf / 150 lbf Distance between arms > 35″ 133 lbf / 200 lbf |
Test #14: 100 lbf / 150 lbf |
Test #14: 100 lbf / 150 lbf |
Distance between arms 100 lbf / 150 lbf Distance between arms > 35″ 133 lbf / 200 lbf |
BIFMA X5.4: same test as |
10. Arm strength test – Vertical – Static |
Armrest width > 200 lbf / 300 lbf Armrest width < 3″ 169 lbf / 253 lbf |
Test #13: 169 lbf / 253 lbf |
Test #13: 200 lbf / 300 lbf |
Armrest width > 200 lbf / 300 lbf Armrest width < 3″ 169 lbf / 253 lbf |
BIFMA X5.4: same test as |
11. Arm durability Test – Horizontal |
100 lbf, 50 000 cycles |
No such requirement |
No such requirement |
100 lbf, 50 000 cycles |
BIFMA X5.4: same test as |
12. Arm durability Test |
150 lbf, 10 000 cycles |
No such requirement |
No such requirement |
150 lbf, 10 000 cycles |
BIFMA X5.4: same test as |
13. Arm durability Test |
100 lbf, 60 000 cycles |
Test #21: 90 lbf, 60 000 cycles |
Test #19: 100 lbf, 60 000 cycles |
90 lbf, 60 000 cycles |
BIFMA X5.11: same test as BIFMA X5.1 & X5.4: same test protocol, different loads |
14. Seating Durability test |
Seating impact test: Size C: 125 lb test bag Size D: 200 lb test bag Size E: 200 lb test bag 225 lb on each seat positions (except impacted position) |
Test #11 125 lb test bag |
Test #11: 200 lb test bag |
Seating impact test: 125 225 lb on each seat positions (except impacted position) |
BIFMA X5.4: same test BIFMA X5.1 & X5.11: Test followed by Front Corner Load-Ease test |
15. Drop test – Dynamic |
Size C: 225 / 300 lb test Size D: 250 / 350 lb test bag Size E: 275 / 400 lb test bag 225 lb on each seat positions (except impacted position) |
Test #8: 225 / 300 lb |
Test #8: 250 / 350 lb |
225 /300 lb test bag 225 lb on each seat positions (except impacted position) |
BIFMA X5.4: Same test Drop height is 6″ for all tests |
16. Leg strength test – |
Size C: 75 lbf / 113 lbf* Size D: 100 lbf / 113 lbf* Size E: 100 lbf / 113 lbf* * : If unit weight is > 113 lbf, the pull force is the unit weight |
Test #18: 75 lbf / 113 lbf |
Test #18: 100 lbf / 150 lbf |
75 lbf / 113 lbf |
Same test protocol as HCF |
17. Unit Drop Test – Dynamic |
Drop height based on unit Available drop height are 2.4″, 4.7″ and 7.1″ |
No such requirement |
No such requirement |
Same test protocol |
BIFMA X5.4: same test |
18. Caster/chair base |
Size C: 250 lb on seat Size D:400 lb on seat Size E: 600 lb on seat 500 cycles over obstacles 25 000 cycles over flat surface |
Test #17: 250 lb load on seat 2000 cycles over obstacles 98 000 cycles over flat surface |
Test #17: 400 lb load on seat 2000 cycles over obstacles 98 000 cycles over flat surface |
250 lb on seat 500 cycles over obstacles 25 000 cycles over flat surface |
BIFMA X5.4: same test |
19. Swivel cycling test |
Size C: 250 lb on seat Size D:400 lb on seat Size E: 600 lb on seat 120 000 cycles |
Test #9: 250 lb load on seat 60 000 cycles, chair at highest position 60 000 cycles chair at lowest position |
Test #9: 400 lb load on seat 60 000 cycles, chair at highest position 60 000 cycles chair at lowest position |
250 lb on seat 120 000 cycles |
BIFMA X5.4: same test |
20. Tilt mechanism test – Cyclic |
Size C: 225 lb on seat Size D:350 lb on seat Size E: 525 lb on seat 200 000 cycles |
Test #10: 225 lb on seat 300 000 cycles |
Test #10: 350 lb on seat 300 000 cycles |
225 lb on seat 200 000 cycles |
BIFMA X5.4: same test |
21. Rear Stability test |
Non-Tilting units: 6 Tilting units: 13 disks |
Test #12.3: Type I & II chairs: Same as Tilting Type III: Same as Non-Tilting |
Test #12.3: Type I & II chairs: Same as Tilting Type III: Same as Non-Tilting |
Same test protocol |
Same test protocol as HCF |
21.5. Front Stability |
Size C: 135 lb load Size D: 175 lb load fixture Size E: 215 lb load fixture 4.5 lbf horizontal pull force |
Test #12.4: 135 lb load fixture 4,5 lbf horizontal pull force force |
Test #12.4: 175 lb load fixture 4.5 lbf horizontal pull force |
Different test, based on |
BIFMA X5.1 & X5.11: |
21.6. Side Stability for |
Size C: 135 lb load Size D: 175 lb load fixture Size E: 215 lb load fixture 4.5 lbf horizontal pull force |
No such requirement |
No such requirement |
No such requirement |
New test |
21.7. Side Stability for |
Size C: 56 / 79 lb (load Size D: 90 / 125 lb (load on seat / arm) Size E: 135 / 191 lb (load on seat / arm) 4.5 lbf horizontal pull force |
No such requirement |
No such requirement |
No such requirement |
New test |
22. Tablet Arm Load Ease Test – Cyclic |
55 lb load, |
Test #24 77 lb load, 100 000 cycles |
Test #22: 55 lb load, 100 000 cycles |
77 lb load, 100 000 cycles, different load location |
BIFMA X5.1 & X5.11: BIFMA X5.4: different test |
23. Tablet Arm Static Load Test |
150 lb load |
Test #23 150 lb load |
Test #21 150 lb load |
150 lb load |
Same test protocol as HCF |
24. Structural Durability Test – Cyclic |
Seat load: 15 lb / inch Side load: 100 lbf, 100 000 cycles |
No such requirement in Side load: 75 lbf, 25 000 cycles |
Seat load: 350 lb Side load: 100 lbf, 50 000 cycles |
No such requirement |
BIFMA HCF 8.2 seat load |
25. Recliner and Legrest |
Load on Legrest / Seat / Size C: 25 / 112.5 / 112.5 lb Size D: 40 / 180 / 180 lb Size E: 60 / 270 / 270 lb 25 000 cycles |
No such requirement |
No such requirement |
No such requirement |
New test |
26. Legrest Strength Test |
75 lbf / 113 lbf |
No such requirement |
No such requirement |
No such requirement |
New test |
Specific tests not required in HCF 8.2 |
|||||
ANSI/BIFMA X5.1 – Test # 7 Base Test – Static |
|||||
ANSI/BIFMA X5.1 – Test #19 Footrest Static Load Test – Vertical |
|||||
ANSI/BIFMA X5.1 – Test #19 Footrest Durability Test – Vertical – Cyclic |
|||||
ANSI/BIFMA X5.1 – Test #22 & ANSI/BIFMA X5.11 – Test #20 – Out Stop Test |
|||||
ANSI/BIFMA X5.1 & X5.11 – Test #11.4 Front Corner Load Ease Test – Cyclic – Off-Center |